Ιδρυματικό Αποθετήριο
Πολυτεχνείο Κρήτης
EN  |  EL

Αναζήτηση

Πλοήγηση

Ο Χώρος μου

Particle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facility

Κατσίβελα Ελευθερία, Λάτος Εμμανουήλ, Raisi Louisa, Αλεξανδροπούλου Βικτώρια, Lazaridis Michalis

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/49CD3A93-CFB7-48AA-92E8-545ED5376821-
Αναγνωριστικόhttps://link.springer.com/article/10.1007%2Fs10453-016-9470-2-
Αναγνωριστικόhttps://doi.org/10.1007/s10453-016-9470-2-
Γλώσσαen-
Μέγεθος18 pagesen
ΤίτλοςParticle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facilityen
ΔημιουργόςΚατσίβελα Ελευθερίαel
ΔημιουργόςKatsivela Eleftheriaen
ΔημιουργόςΛάτος Εμμανουήλel
ΔημιουργόςLatos Emmanouilen
ΔημιουργόςRaisi Louisaen
ΔημιουργόςΑλεξανδροπούλου Βικτώριαel
ΔημιουργόςAleksandropoulou Victoriaen
ΔημιουργόςAlexandropoulou Victoriaen
ΔημιουργόςLazaridis Michalisen
ΔημιουργόςΛαζαριδης Μιχαληςel
ΕκδότηςSpringerOpenen
ΠερίληψηA field study was performed to identify the size distribution characteristics of viable, cultivable airborne microorganisms (heterotrophic bacteria, fungi, and total coliforms) at a municipal wastewater treatment facility, and their association with inhalable particulate matter (PM1, PM2.5, and PM10), as well as hydrogen sulfide concentrations and ambient meteorological parameters. The highest concentrations of cultivable, airborne heterotrophic bacteria, total coliforms, mass and number concentration of particulate matter, as well as hydrogen sulfide were observed at the aerated grit removal chambers at the pretreatment stage (3 to 2030 times higher than the values of the background ambient air). In contrast, the mean concentrations of cultivable, airborne mesophilic fungi at the aerated grit chambers were 0.6 time lower than the background site, where fungi presented the most abundant taxonomic group in the ambient air. Although the highest concentrations of the airborne fungi were determined at aerodynamic diameters between 2.1 and 3.3 μm, a nearly equal distribution of the mean concentrations of the cultivable, airborne heterotrophic bacteria were observed in the six different size fractions at the primary settling tanks and in the ambient air. Interestingly, their size distribution profiles at the aerated grit chambers were different and showed a maximum aerodynamic diameter at the size range from 3.3 to 4.7 μm, similar to that of the cultivable, airborne total coliforms. In general, low positive or no significant linear relationships could be found between the cultivable airborne heterotrophic bacteria, total coliforms, or fungi at the two wastewater treatment stages and the ambient background microbial community. en
ΤύποςPeer-Reviewed Journal Publicationen
ΤύποςΔημοσίευση σε Περιοδικό με Κριτέςel
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2018-03-29-
Ημερομηνία Δημοσίευσης2017-
Θεματική ΚατηγορίαBacteriaen
Θεματική ΚατηγορίαBioaerosolsen
Θεματική ΚατηγορίαFungien
Θεματική ΚατηγορίαParticle size distributionen
Θεματική ΚατηγορίαParticulate matteren
Θεματική ΚατηγορίαWastewateren
Βιβλιογραφική ΑναφοράE. Katsivela, E. Latos, L. Raisi, V. Aleksandropoulou and M. Lazaridis, "Particle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facility," Aerobiologia, vol. 33, no. 3, pp. 297-314, Sept. 2017. doi : 10.1007/s10453-016-9470-2en

Υπηρεσίες

Στατιστικά