Ιδρυματικό Αποθετήριο
Πολυτεχνείο Κρήτης
EN  |  EL

Αναζήτηση

Πλοήγηση

Ο Χώρος μου

Limitations of an amorphous‐metal magnetometer operated by modulating the magnetostrictive strain

Pantinakis Apostolos, D. A. Jackson

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/54BEE383-3468-4AE6-9443-E0F762BE8687-
Αναγνωριστικόhttps://doi.org/10.1063/1.342732-
Γλώσσαen-
ΤίτλοςLimitations of an amorphous‐metal magnetometer operated by modulating the magnetostrictive strainen
ΔημιουργόςPantinakis Apostolosen
ΔημιουργόςΠαντινακης Αποστολοςel
ΔημιουργόςD. A. Jacksonen
ΕκδότηςAmerican Institute of Physicsen
ΠερίληψηAn analysis is presented of the characteristics of a magnetometer which uses an amorphous‐metal ribbon as its primary sensing element and which operates by modulating the magnetostrictive strain. Magnetic fields at the second harmonic of the modulation frequency are identified as capable of significantly degrading the magnetometer performance. A second‐harmonic field is measured and its contribution to the noise is estimated.en
ΤύποςPeer-Reviewed Journal Publicationen
ΤύποςΔημοσίευση σε Περιοδικό με Κριτέςel
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2015-10-24-
Ημερομηνία Δημοσίευσης1989-
Βιβλιογραφική ΑναφοράPantinakis, A. and Jackson, D.A. "Limitations of an amorphous-metal magnetometer operated by modulating the magnetostrictive strain", Journal of Applied Physics, Vol. 65, no. 7, pp. 2872, 1989. Doi:10.1063/1.342732.en