Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Relationship between airborne microbial and particulate matter concentrations in the ambient air at a Meditearranean site

Lazaridis Michalis, Katsivela, Eleftheria, 1961-, Frueherer Name, Raisi ,L

Simple record


URIhttp://purl.tuc.gr/dl/dias/2194D0BE-DFCE-4086-ADE6-016C97670ECE-
Identifierhttp://journal.gnest.org/sites/default/files/Journal%20Papers/84-91_694_Katsivela_12-1.pdf-
Languageen-
Extent8 pagesen
TitleRelationship between airborne microbial and particulate matter concentrations in the ambient air at a Meditearranean site en
CreatorLazaridis Michalisen
CreatorΛαζαριδης Μιχαληςel
CreatorKatsivela, Eleftheria, 1961-, Frueherer Nameen
CreatorRaisi ,L en
Content SummaryThe relationship between the viable airborne bacterial and fungal concentrations and the respirable particulate matter with aerodynamic diameter less than 10 µm (PM10), 2.5 µm (PM2.5), and 1 µm (PM1) in the ambient air was studied. An Andersen six stage viable particle sampler and a MAS 100 sampler were used for microbial measurements. Duplicates of samples were collected at each sampling period (20 campaigns in total) at a residential site in the city of Chania (Crete, Greece) during April, May and June 2008. Mean concentration of the total sum of the six size fractions was 79 + 41 CFU m-3 for mesophilic heterotrophic bacteria, whereas for mesophilic fungi it was five times higher (395 + 338 CFU m-3). Particulate matter measurements at the same time period at the same site revealed that the mean concentrations of PM10, PM2.5, and PM1 were 46 + 14, 35 + 14, and 28 + 12 µg m-3, respectively, whereas the mean cumulate counts of PM1 particles was 5,059 + 1,973 particles cm-3. The mean arithmetic concentration of the size distribution of the airborne fungi had a maximum at aerodynamic diameters between 2.1 and 3.3 µm. However, a maximum was not observed for the mean arithmetic concentration of the size distribution of the airborne heterotrophic bacteria. It was also observed that concentrations of airborne bacteria and fungi outdoors were highly variable and do not correlate with the particle number (PM1) or mass concentration of PM10, PM2.5 and PM1. Thereby, the R2 -values in all correlations were less than 0.3. However, the concentrations of airborne bacteria and fungi were decreased with increasing mass concentrations of PM10, PM2.5, or PM1 while were increased with increasing number concentration of PM1. In addition, the concentrations of airborne bacteria were increased with increasing concentrations of airborne fungi. Finally, the microbial or the particulate matter data did not correlate with meteorological parameters, such as temperature, relative humidity, wind speed and UV radiation in ambient conditions. en
Type of ItemPeer-Reviewed Journal Publicationen
Type of ItemΔημοσίευση σε Περιοδικό με Κριτέςel
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2015-11-12-
Date of Publication2010-
SubjectAir--Pollution--Controlen
SubjectAir contaminantsen
SubjectAir pollutantsen
SubjectAir pollutionen
SubjectAir pollution controlen
SubjectAir toxicsen
SubjectAirborne pollutantsen
SubjectAtmosphere--Pollutionen
SubjectContaminants, Airen
SubjectControl of air pollutionen
SubjectPollutants, Airen
SubjectToxics, Airen
Subjectair pollutionen
Subjectair pollution controlen
Subjectair contaminantsen
Subjectair pollutantsen
Subjectair toxicsen
Subjectairborne pollutantsen
Subjectatmosphere pollutionen
Subjectcontaminants airen
Subjectcontrol of air pollutionen
Subjectpollutants airen
Subjecttoxics airen
Bibliographic CitationL. Raisi,M. Lazaridis, E. Katsivela.(2010). Relationship between airborne microbial and particulate matter concentrations in the ambient air at a Meditearranean site. Global Nest Journal [online].pp.84-91.Available:http://journal.gnest.org/sites/default/files/Journal%20Papers/84-91_694_Katsivela_12-1.pdfen

Services

Statistics