Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Identification of “trouble maker(s)” caused by the PLL in multi-paralleled inverters systems

Cheng Yanqi, Wu Weimin, Huang Min, Blaabjerg, Frede, 1963-, Koutroulis Eftychios, Chung Henry

Simple record


URIhttp://purl.tuc.gr/dl/dias/3295DE10-0910-426F-A584-6185E72A89B9-
Identifierhttps://doi.org/10.1109/APEC43599.2022.9773727-
Identifierhttps://ieeexplore.ieee.org/document/9773727-
Languageen-
Extent4 pagesen
TitleIdentification of “trouble maker(s)” caused by the PLL in multi-paralleled inverters systemsen
CreatorCheng Yanqien
CreatorWu Weiminen
CreatorHuang Minen
CreatorBlaabjerg, Frede, 1963-en
CreatorKoutroulis Eftychiosen
CreatorΚουτρουλης Ευτυχιοςel
CreatorChung Henryen
PublisherInstitute of Electrical and Electronics Engineersen
DescriptionThis work was performed within the framework of the project “eSOLAR: Principle and Control of High-Efficiency Buck-Boost Type Photovoltaic Inverter” of the program Bilateral and Multilateral Research and Technology cooperation between Greece and China, funded by the Operational Program Competitiveness, Entrepreneurship and Innovation 2014-2020 (co-funded by the European Regional Development Fund) and managed by the General Secretariat of Research and Technology, Ministry of Education, Research, and Religious Affairs, Greece, under project eSOLAR/T71KI-00066.en
Content SummaryIn this paper, it is shown that in multi-paralleled inverters power systems, when the internal instability which is caused by an improperly designed phase-locked loop (PLL) takes place, the root mean square (RMS) value of the grid-injected current at the fundamental frequency of the “trouble maker(s)” will be lower than its reference value. The theoretical analysis is first carried out in details. Then, a diagnosis method is proposed to detect the exact “trouble maker(s)” and the PLL bandwidth of the “trouble maker(s)” can be adjusted online to continue injecting energy into the power grid. Finally, experimental results are presented, which verify the effectiveness of the proposed method.en
Type of ItemΠλήρης Δημοσίευση σε Συνέδριοel
Type of ItemConference Full Paperen
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2024-08-23-
Date of Publication2022-
SubjectGrid-connected DC/AC inverteren
SubjectMulti-paralleled invertersen
SubjectAuto-identification methoden
SubjectLCL-filteren
Bibliographic CitationY. Cheng, W. Wu, M. Huang, F. Blaabjerg, E. Koutroulis and H. Chung, "Identification of “trouble maker(s)” caused by the PLL in multi-paralleled inverters systems," in Proceedings of the 2022 IEEE Applied Power Electronics Conference and Exposition (APEC 2022), Houston, TX, USA, 2022, pp. 753-756, doi: 10.1109/APEC43599.2022.9773727.en

Services