Open-circuit fault diagnosis and fault-tolerant control for coupled-inductor-based Aalborg inverter

Xiao Chengqi, Wu Weimin, Chen Jianming, Lu Gang, Koutroulis Eftychios, Chung Henry, Blaabjerg, Frede, 1963-

Full record


URI: http://purl.tuc.gr/dl/dias/113B6261-0A6B-4375-BE75-481B35A9377F
Year 2022
Type of Item Conference Full Paper
License
Details
Bibliographic Citation C. Xiao, W. Wu, J. Chen, G. Lu, E. Koutroulis, H. S.-H. Chung, and F. Blaabjerg, "Open-circuit fault diagnosis and fault-tolerant control for coupled-inductor-based Aalborg inverter," in Proceedings of the 2022 IEEE Energy Conversion Congress and Exposition (ECCE 2022), Detroit, MI, USA, 2022, doi: 10.1109/ECCE50734.2022.9947854. https://doi.org/10.1109/ECCE50734.2022.9947854
Appears in Collections

Summary

In this paper, an open-circuit fault diagnosis and fault-tolerant control method of SiC-MOSFET for the coupled-inductor-based Aalborg inverter is proposed. The method detects open-circuit faults by calculating the slope of the sampling current, and identifies the faulty SiC-MOSFET devices through a reconfiguration control algorithm. In any operating mode of the coupled-inductor-based Aalborg inverter, when the high-frequency switch tube has an open-circuit fault, the inverter can be reconfigured as a Fly-Back-type or Fly-Boost-type converter to continue operating. The proposed method enhances the reliability of the inverter and does not require additional sensors or diagnostic circuits, thus not increasing the cost of the overall system.