Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

On-chip power line communication for cascaded H-bridge power converters

Mandourarakis Ioannis, Agorastou Zoi, Koutroulis Eftychios, Karystinos Georgios, Siskos Stylianos

Simple record


URIhttp://purl.tuc.gr/dl/dias/4EA0B7BC-3157-43A7-85D5-5CED1435F02D-
Identifierhttps://doi.org/10.1109/MOCAST54814.2022.9837618-
Identifierhttps://ieeexplore.ieee.org/document/9837618-
Languageen-
Extent5 pagesen
TitleOn-chip power line communication for cascaded H-bridge power convertersen
CreatorMandourarakis Ioannisen
CreatorΜανδουραρακης Ιωαννηςel
CreatorAgorastou Zoien
CreatorKoutroulis Eftychiosen
CreatorΚουτρουλης Ευτυχιοςel
CreatorKarystinos Georgiosen
CreatorΚαρυστινος Γεωργιοςel
CreatorSiskos Stylianosen
PublisherInstitute of Electrical and Electronics Engineersen
DescriptionThis research has been co‐financed by the European Regional Development Fund of the European Union and Greek national funds through the Operational Program Competitiveness, Entrepreneurship and Innovation, under the call RESEARCH–CREATE–INNOVATE (project code: T1EDK-01485).en
Content SummaryDistributed power generators and power converters are widely incorporated in modern microgrid and smart grid structures, which require data links among the source and load sites for monitoring and control. This paper proposes a novel power line communication (PLC) system design fabricated in an integrated circuit using the XFAB XH018 0.18μm CMOS technology to enable the data linking capabilities in such decentralized units. The proposed on-chip PLC system can be used in cascaded H-bridge power converters connected on a common DC or AC bus without requiring additional circuitry for transmitting the information. Also, its operation does not depend on the scale or type of the supplied load. An experimental prototype system for the power and data transmission, including the fabricated PLC chip and a field-programmable gate array (FPGA) device for the data reception, has been developed and tested. The experimental results verify the feasibility and effectiveness of the proposed on-chip PLC system.en
Type of ItemΠλήρης Δημοσίευση σε Συνέδριοel
Type of ItemConference Full Paperen
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2024-10-24-
Date of Publication2022-
SubjectPower line communicationen
SubjectPower converteren
SubjectCascaded H-bridgeen
SubjectSmart griden
SubjectPhotovoltaicen
Bibliographic CitationI. Mandourarakis, Z. Agorastou, E. Koutroulis, G. N. Karystinos and S. Siskos, "On-chip power line communication for cascaded H-bridge power converters," in Proceedings of the 11th International Conference on Modern Circuits and Systems Technologies (MOCAST 2022), Bremen, Germany, 2022, doi: 10.1109/MOCAST54814.2022.9837618.en

Services

Statistics