Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Control of cascaded H-bridge converters for power line communication

Mandourarakis Ioannis, Koutroulis Eftychios, Karystinos Georgios

Simple record


URIhttp://purl.tuc.gr/dl/dias/AFA03EFC-5C92-4670-985A-6EA92E808016-
Identifierhttps://doi.org/10.1109/IECON49645.2022.9969079-
Identifierhttps://ieeexplore.ieee.org/document/9969079-
Languageen-
Extent6 pagesen
TitleControl of cascaded H-bridge converters for power line communicationen
CreatorMandourarakis Ioannisen
CreatorΜανδουραρακης Ιωαννηςel
CreatorKoutroulis Eftychiosen
CreatorΚουτρουλης Ευτυχιοςel
CreatorKarystinos Georgiosen
CreatorΚαρυστινος Γεωργιοςel
PublisherInstitute of Electrical and Electronics Engineersen
DescriptionThis research has been co‐financed by the European Regional Development Fund of the European Union and Greek national funds through the Operational Program Competitiveness, Entrepreneurship and Innovation, under the call RESEARCH–CREATE–INNOVATE (project code: T1EDK-01485).en
Content SummaryPower line communication (PLC) technological advancements are currently being led by the interoperation needs in applications such as smart grids, building energy management systems, electric vehicles, and the Internet of Things. In this paper, alternative control schemes are proposed and compared for the simultaneous transmission of power and digital data through the power circuits of the modules synthesizing a single-phase cascaded H-bridge multilevel inverter. The proposed PLC method does not require any additional circuit elements in the power loop for the PLC implementation. Special focus is paid to the control schemes applied to the H-bridge driving circuits to produce a low total harmonic distortion (THD) without compromising the reliability of data communication. Various parametric simulation models are designed and tested using time-division multiplexing with two variations over the assignment technique for the PLC communication task. The results suggest that the proposed low-bandwidth PLC design is robust enough to provide the required communication fidelity and capable of successfully transmitting the mixed-signal (i.e., power and data) through the power cable under various operating conditions.en
Type of ItemΠλήρης Δημοσίευση σε Συνέδριοel
Type of ItemConference Full Paperen
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2024-12-10-
Date of Publication2022-
SubjectPower line communicationen
SubjectTotal harmonic distortionen
SubjectMultilevel inverteren
SubjectCascaded H-bridgeen
SubjectSinusoidal pulse width modulationen
Bibliographic CitationI. Mandourarakis, E. Koutroulis and G. N. Karystinos, "Control of cascaded H-bridge converters for power line communication," in Proceedings of the 48th Annual Conference of the IEEE Industrial Electronics Society (IECON 2022), Brussels, Belgium, 2022, doi: 10.1109/IECON49645.2022.9969079.en

Services

Statistics