A new control strategy with simplified model and Kalman filter estimator for grid-tied inverter with asymmetric LCL filter

Gao Chunxiao, Wu Weimin, Koutroulis Eftychios, Chen Jianming, Lu Gang, Blaabjerg, Frede, 1963-

Full record


URI: http://purl.tuc.gr/dl/dias/67ACBBD9-41E8-4639-B613-0D5E68E2A6C6
Year 2022
Type of Item Conference Full Paper
License
Details
Bibliographic Citation C. Gao, W. Wu, E. Koutroulis, J. Chen, G. Lu and F. Blaabjerg, "A new control strategy with simplified model and Kalman filter estimator for grid-tied inverter with asymmetric LCL filter," in Proceedings of the 48th Annual Conference of the IEEE Industrial Electronics Society (IECON 2022), Brussels, Belgium, 2022, doi: 10.1109/IECON49645.2022.9968598. https://doi.org/10.1109/IECON49645.2022.9968598
Appears in Collections

Summary

In grid-connected inverter systems, the three-phase asymmetric LCL (A-LCL) filter has outstanding characteristics of simple structure, almost the smallest total inductance, and the strong resistance to the adverse effects of parameter shifts. Nevertheless, the order of this kind of power filter is high, and the control model is complicated due to its asymmetric structure. In this paper, a simplified modeling method, which effectively reduces the system order is proposed, without affecting the control performance. Then, the Kalman filter estimation (KF-estimation) is adopted to reconstruct the PCC voltage. A 380 V/50 Hz/6 kW three-phase laboratory setup has been developed to verify the correctness and effectiveness of the proposed control strategy.