Evaluation of common-mode leakage current of Aalborg-type transformerless PV inverters

Orfanoudakis, G. I, Koutroulis Eftychios, Foteinopoulos Georgios, Wu Weimin

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/A9C665A0-31DE-4AD5-9FAC-FA2F4A7529D2-
Αναγνωριστικόhttps://ieeexplore.ieee.org/document/9907343-
Γλώσσαen-
Μέγεθος10 pagesen
ΤίτλοςEvaluation of common-mode leakage current of Aalborg-type transformerless PV invertersen
ΔημιουργόςOrfanoudakis, G. Ien
ΔημιουργόςKoutroulis Eftychiosen
ΔημιουργόςΚουτρουλης Ευτυχιοςel
ΔημιουργόςFoteinopoulos Georgiosen
ΔημιουργόςΦωτεινοπουλος Γεωργιοςel
ΔημιουργόςWu Weiminen
ΕκδότηςInstitute of Electrical and Electronics Engineersen
ΠεριγραφήThis work was performed within the framework of the project “eSOLAR: Principle and control of high-efficiency Buck-Boost type Photovoltaic inverter” of the program “Bilateral and Multilateral Research & Technology Co-operation between Greece and China”, funded in Greece by the Operational Program “Competitiveness, Entrepreneurship and Innovation 2014-2020” (co-funded by the European Regional Development Fund) and managed by the General Secretariat of Research and Technology, Ministry of Education, Research, and Religious Affairs under the project eSOLAR/T7ΔKI-00066.en
ΠερίληψηSingle-phase transformerless photovoltaic (PV) inverters with voltage step-up capability are widely employed for integrating PV generation to the electric grid. Transformerless PV inverter topologies include special features to suppress common-mode (CM) leakage currents that can flow through parasitic capacitances that appear between the PV array and the ground. The Aalborg inverter belongs to the family of dual-mode time-sharing PV inverters, in which a voltage step-up (Boost) stage operates alternatively to a step-down (Buck) stage to create a rectified sine wave DC-link voltage, which is then unfolded to the grid. This paper analyses, quantifies and improves CM leakage current generation for Aalborg-type transformerless PV inverters. It highlights the factors that can lead to high peak and RMS values of leakage current for these topologies and proposes an output filter modification to reduce them by up to 70%. The analytical results are supported by simulation in MATLAB-Simulink and are applicable to other topologies with rectified sine wave DC-link voltages.en
ΤύποςΠλήρης Δημοσίευση σε Συνέδριοel
ΤύποςConference Full Paperen
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2024-12-19-
Ημερομηνία Δημοσίευσης2022-
Θεματική ΚατηγορίαGrid-connected inverteren
Θεματική ΚατηγορίαTransformerless PV inverteren
Θεματική ΚατηγορίαDual-mode time-sharing inverteren
Θεματική ΚατηγορίαBuck in Buck, Boost in Boost inverteren
Θεματική ΚατηγορίαStep-up inverteren
Θεματική ΚατηγορίαRectified sine wave DC-link voltageen
Θεματική ΚατηγορίαAalborg inverteren
Θεματική ΚατηγορίαCommon-mode currenten
Θεματική ΚατηγορίαGround leakage currenten
Βιβλιογραφική ΑναφοράG. I. Orfanoudakis, E. Koutroulis, G. Foteinopoulos and W. Wu, "Evaluation of common-mode leakage current of Aalborg-type transformerless PV inverters," in Proceedings of the 24th European Conference on Power Electronics and Applications (EPE 2022 ECCE Europe), Hanover, Germany, 2022.en