URI | http://purl.tuc.gr/dl/dias/206CF5B6-2544-410B-8889-6600B8B14A79 | - |
Identifier | https://doi.org/10.26233/heallink.tuc.19671 | - |
Language | en | - |
Extent | 125 pages | el |
Title | Spectral deconvolution and concentration mapping in complex biochemical stains | en |
Creator | Abatzi Fani | en |
Creator | Αμπατζη Φανη | el |
Contributor [Thesis Supervisor] | Balas Costas | en |
Contributor [Thesis Supervisor] | Μπαλας Κωστας | el |
Contributor [Assistant] | Epitropou Georgios | en |
Contributor [Assistant] | Επιτροπου Γεωργιος | el |
Contributor [Committee Member] | Zervakis Michalis | en |
Contributor [Committee Member] | Ζερβακης Μιχαλης | el |
Contributor [Committee Member] | Maravelaki Pagona | en |
Contributor [Committee Member] | Μαραβελακη Παγωνα | el |
Publisher | Technical University of Crete | en |
Publisher | Πολυτεχνείο Κρήτης | el |
Academic Unit | Technical University of Crete::School of Electronic and Computer Engineering | en |
Academic Unit | Πολυτεχνείο Κρήτης::Σχολή Ηλεκτρονικών Μηχανικών και Μηχανικών Υπολογιστών | el |
Content Summary | Spectral Imaging (SI) combines spectroscopy and imaging, enabling the acquisition of a stack of images at narrow spectral bands comprising the so-called spectral cube. A complete spectrum can be calculated for every image pixel from the multidimensional spatio-spectral space of the cube. This study aims at identifying the concentration of solvents in mixtures of multiple biochemical stains with overlapping spectral signatures. More specifically, a series of experiments has been undertaken via experimental design
arrangements (full factorial, face-centered & half factorial) employing both spectrum acquisition by spectrophotometer and spectral imaging acquisition. Furthermore, an extensive number of algorithmic methods, based on Beer Lambert's law generalization, including Classical Least Squares (CLS), Inverse Least Squares (ILS) with forward or backward selection, Principal Components Regression (PCR) and Partial Least Squares (PLS) has been implemented and applied to both simulated and experimental data. It was found that PLS can predict the concentrations in mixtures of two and three solvents with high accuracy on the datasets of spectral images. The combination of SI
with concentration prediction algorithms can provide a valuable tool for quantitative assessment of the uptake of biological stains in histochemistry applications. | en |
Type of Item | Διπλωματική Εργασία | el |
Type of Item | Diploma Work | en |
License | http://creativecommons.org/licenses/by/4.0/ | en |
Date of Item | 2014-07-10 | - |
Date of Publication | 2014 | - |
Subject | Deconvolution in spectrum analysis | en |
Subject | spectrum analysis deconvolution | en |
Subject | deconvolution in spectrum analysis | en |
Bibliographic Citation | Fani Abatzi, "Spectral deconvolution and concentration mapping in complex biochemical stains", Diploma Work, School of Electronic and Computer Engineering, Technical University of Crete, Chania, Greece, 2014 | en |
Bibliographic Citation | Φανή Αμπατζή, "Spectral deconvolution and concentration mapping in complex biochemical stains", Διπλωματική Εργασία, Σχολή Ηλεκτρονικών Μηχανικών και Μηχανικών Υπολογιστών, Πολυτεχνείο Κρήτης, Χανιά, Ελλάς, 2014 | el |