Ιδρυματικό Αποθετήριο
Πολυτεχνείο Κρήτης
EN  |  EL

Αναζήτηση

Πλοήγηση

Ο Χώρος μου

Vortex-assisted liquid-liquid microextraction of octylphenol, nonylphenol and bisphenol-A

Elefteria Psillakis, Evangelia Yiantzi, Konstantina Tyrovola, Nicolas Kalogerakis

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/2C190A94-F49C-4D26-95DA-2151C92E59C8-
Αναγνωριστικόhttps://doi.org/10.1016/j.talanta.2009.11.005-
Γλώσσαen-
Μέγεθος6 pagesen
ΤίτλοςVortex-assisted liquid-liquid microextraction of octylphenol, nonylphenol and bisphenol-Aen
ΔημιουργόςElefteria Psillakisen
ΔημιουργόςEvangelia Yiantzien
Δημιουργός Konstantina Tyrovolaen
ΔημιουργόςNicolas Kalogerakisen
ΕκδότηςElsevieren
ΠερίληψηA new and fast equilibrium-based solvent microextraction technique termed vortex-assisted liquid–liquid microextraction (VALLME) has been developed and used for the trace analysis of octylphenol, nonylphenol and bisphenol-A in water and wastewater samples. According to VALLME, dispersion of microvolumes of a low density extractant organic solvent into the aqueous sample is achieved by using for the first time vortex mixing, a mild emulsification procedure. The fine droplets formed could extract target analytes towards equilibrium faster because of the shorter diffusion distance and larger specific surface area. Upon centrifugation the floating extractant acceptor phase restored its initial single microdrop shape and was used for high-performance liquid chromatographic analysis. Different experimental parameters were controlled and the optimum conditions found were: 50l of octanol as the extractant phase; 20 ml aqueous donor samples; a 2 min vortex extraction time with the vortex agitator set at a 2500rpm rotational speed; centrifugation for 2 min at 3500 rpm; no ionic strength or pH adjustment. The calculated calibration curves gave high levels of linearity yielding correlation coefficients (r2) greater than 0.9935. The repeatability and reproducibility of the proposed method were found to be good and the limits of the detection were calculated in the low g l−1 level ranging between 0.01 and 0.07g l−1. Matrix effects were determined by applying the proposed method to spiked tap, river water and treated municipal wastewater samples.en
ΤύποςPeer-Reviewed Journal Publicationen
ΤύποςΔημοσίευση σε Περιοδικό με Κριτέςel
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2015-09-24-
Ημερομηνία Δημοσίευσης2010-
Βιβλιογραφική ΑναφοράE. Yiantzi, E. Psillakis , K. Tyrovola, N. Kalogerakis , "Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol and bisphenol-A " ,Tal.,vol. 80,no.5 ,pp.2057–2062,2010.doi:10.1016/j.talanta.2009.11.005en

Διαθέσιμα αρχεία

Υπηρεσίες

Στατιστικά