Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Analysis of polycyclic aromatic hydrocarbons in wastewater treatment plant effluents using hollow fibre liquid phase microextraction

Charalabaki Magdalini , Psyllaki Eleftheria, Mantzavinos Dionysis, Kalogerakis Nikos

Simple record


URIhttp://purl.tuc.gr/dl/dias/0192EBDA-B136-4F83-AA35-E8FBC047B32F-
Identifierhttps://doi.org/ 10.1016/j.chemosphere.2005.01.040-
Identifierhttp://www.sciencedirect.com/science/article/pii/S0045653505001888-
Languageen-
Extent8 pagesen
TitleAnalysis of polycyclic aromatic hydrocarbons in wastewater treatment plant effluents using hollow fibre liquid phase microextractionen
CreatorCharalabaki Magdalini en
CreatorPsyllaki Eleftheriaen
CreatorΨυλλακη Ελευθεριαel
CreatorMantzavinos Dionysisen
CreatorΜαντζαβινος Διονυσηςel
CreatorKalogerakis Nikosen
CreatorΚαλογερακης Νικοςel
PublisherElsevieren
Content SummaryA simple and efficient method for the enrichment of low molecular weight polycyclic aromatic hydrocarbons (PAHs) in effluents originating from wastewater treatment plants is presented here. The proposed protocol couples the recently introduced hollow fibre liquid-phase microextraction (LPME) method with gas chromatography–mass spectrometry. Method parameters were controlled and the optimised experimental conditions were: 5 ml aqueous samples, containing 2.5% NaCl w/v, stirred at 1000 rpm, extracted with toluene for 15 min. The developed protocol yielded a linear calibration curve in the concentration range from 0.5 to 50 lg l1 for all target analytes (namely acenaphthene, phenanthrene, fluoranthene and pyrene) and limits of detection in the low lg l1 level (0.005–0.011 lg l1). The repeatability and interday precision of the method varied between 2.7% and 11.3% and 7.9% and 14.4% respectively. The relative recoveries from different types of natural water samples revealed that matrix had a small effect on the hollow fibre LPME process. The developed method was then applied for the determination of PAHs contamination in effluent samples taken from two major municipal wastewater treatment plants. The results were compared with those obtained with solid-phase microextraction. The ability of both microextraction methods to concentrate organic analytes was demonstrated as both methods confirmed the presence of PAHs as well as of phthalates in the examined effluent samples.en
Type of ItemPeer-Reviewed Journal Publicationen
Type of ItemΔημοσίευση σε Περιοδικό με Κριτέςel
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2015-09-24-
Date of Publication2005-
SubjectWastewater analysisen
SubjectPAHsen
SubjectHollow fibre LPMEen
SubjectSolvent microextractionen
SubjectExtraction methoden
Bibliographic CitationM. Charalabaki, E. Psillakis, D. Mantzavinos and N. Kalogerakis, "Analysis of polycyclic aromatic hydrocarbons in wastewater treatment plant effluents using hollow fibre liquid phase microextraction ", Chemosp., vol. 60, no. 5, pp. 690-698, Jul. 2005 doi: 10.1016/j.chemosphere.2005.01.040en

Services