Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Particle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facility

Κατσίβελα Ελευθερία, Λάτος Εμμανουήλ, Raisi Louisa, Αλεξανδροπούλου Βικτώρια, Lazaridis Michalis

Full record


URI: http://purl.tuc.gr/dl/dias/49CD3A93-CFB7-48AA-92E8-545ED5376821
Year 2017
Type of Item Peer-Reviewed Journal Publication
License
Details
Bibliographic Citation E. Katsivela, E. Latos, L. Raisi, V. Aleksandropoulou and M. Lazaridis, "Particle size distribution of cultivable airborne microbes and inhalable particulate matter in a wastewater treatment plant facility," Aerobiologia, vol. 33, no. 3, pp. 297-314, Sept. 2017. doi : 10.1007/s10453-016-9470-2 https://doi.org/10.1007/s10453-016-9470-2
Appears in Collections

Summary

A field study was performed to identify the size distribution characteristics of viable, cultivable airborne microorganisms (heterotrophic bacteria, fungi, and total coliforms) at a municipal wastewater treatment facility, and their association with inhalable particulate matter (PM1, PM2.5, and PM10), as well as hydrogen sulfide concentrations and ambient meteorological parameters. The highest concentrations of cultivable, airborne heterotrophic bacteria, total coliforms, mass and number concentration of particulate matter, as well as hydrogen sulfide were observed at the aerated grit removal chambers at the pretreatment stage (3 to 2030 times higher than the values of the background ambient air). In contrast, the mean concentrations of cultivable, airborne mesophilic fungi at the aerated grit chambers were 0.6 time lower than the background site, where fungi presented the most abundant taxonomic group in the ambient air. Although the highest concentrations of the airborne fungi were determined at aerodynamic diameters between 2.1 and 3.3 μm, a nearly equal distribution of the mean concentrations of the cultivable, airborne heterotrophic bacteria were observed in the six different size fractions at the primary settling tanks and in the ambient air. Interestingly, their size distribution profiles at the aerated grit chambers were different and showed a maximum aerodynamic diameter at the size range from 3.3 to 4.7 μm, similar to that of the cultivable, airborne total coliforms. In general, low positive or no significant linear relationships could be found between the cultivable airborne heterotrophic bacteria, total coliforms, or fungi at the two wastewater treatment stages and the ambient background microbial community.

Services

Statistics