Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Vacuum-assisted headspace single-drop microextraction: eliminating interfacial gas-phase limitations

Psyllaki Eleftheria, Koutela Niki, Colussi Agustín J.

Simple record


URIhttp://purl.tuc.gr/dl/dias/55A8611A-AFD4-4F75-A2A1-DB0A8B445E21-
Identifierhttps://doi.org/10.1016/j.aca.2019.09.056-
Identifierhttps://www.sciencedirect.com/science/article/pii/S0003267019311432-
Languageen-
Extent8 pagesen
TitleVacuum-assisted headspace single-drop microextraction: eliminating interfacial gas-phase limitationsen
CreatorPsyllaki Eleftheriaen
CreatorΨυλλακη Ελευθεριαel
CreatorKoutela Nikien
CreatorΚουτελα Νικηel
CreatorColussi Agustín J.en
PublisherElsevieren
Content SummaryGas-phase limitations have been neglected in headspace single-drop microextraction (HS-SDME) and rate control has been assumed to primarily reside in the liquid water and/or organic phases, but not in the headspace. Herein we demonstrate the presence of interfacial gas constraints and propose using reduced headspace pressures to remove them. To describe the pressure dependence of HS-SDME, the system was decoupled into two interfacial steps: (i) the evaporation step (water-headspace interface) formulated using the two-film theory and (ii) the analyte uptake by the microdrop (headspace-microdrop interface) formulated using the resistance model. Naphthalene, acenaphthene, and pyrene were chosen as model analytes for their large Henry's law solubility constants in n-octanol (HOA > 103 M atm−1), and their low to moderate Henry's law volatility constants in water as a solvent (KH). We have found that extraction times were significantly shortened for all analytes by sampling at pressures well below the 1 atm used in the standard HS-SDME procedure. The acceleration of naphthalene extraction, whose facile evaporation into the headspace had been assumed to be practically pressure independent, highlighted the role of mass transfer through the interfacial gas layer on the organic solvent drop. The larger accelerations observed for acenaphthene and (especially) pyrene upon reducing the sampling pressure, suggested that gas-sided constraints were important during both the evaporation and uptake steps. Model calculations incorporating mass transfers at the headspace-microdrop interface confirmed that gas-phase resistance is largely eliminated (>96%) when reducing the sampling pressure from 1 to 0.04 atm, an effect that is nearly independent of analyte molecular mass. The relative importance of the two interfacial steps and their gas- and liquid-phase limitations are discussed, next to the use of KH and HOA to predict the positive effect of vacuum on HS-SDME.en
Type of ItemPeer-Reviewed Journal Publicationen
Type of ItemΔημοσίευση σε Περιοδικό με Κριτέςel
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2020-03-31-
Date of Publication2019-
SubjectAnalyte evaporationen
SubjectAnalyte uptakeen
SubjectGas constraintsen
SubjectHeadspace single drop microextractionen
SubjectReduced pressureen
SubjectVacuum-assisted headspace single drop microextractionen
Bibliographic CitationE. Psillakis, N. Koutela and A.J. Colussi, "Vacuum-assisted headspace single-drop microextraction: eliminating interfacial gas-phase limitations," Anal. Chim. Acta, vol. 1092, pp. 9-16, Dec. 2019. doi: 10.1016/j.aca.2019.09.056en