URI | http://purl.tuc.gr/dl/dias/D6A35CC5-068F-4C00-850F-3DA651E65564 | - |
Αναγνωριστικό | https://doi.org/10.1016/j.neuroimage.2021.118726 | - |
Αναγνωριστικό | https://www.sciencedirect.com/science/article/pii/S1053811921009988 | - |
Γλώσσα | en | - |
Μέγεθος | 15 pages | en |
Τίτλος | Reconstructing subcortical and cortical somatosensory activity via the RAMUS inverse source analysis technique using median nerve SEP data | en |
Δημιουργός | Rezaei Atena | en |
Δημιουργός | Lahtinen Joonas | en |
Δημιουργός | Neugebauer Frank | en |
Δημιουργός | Antonakakis Marios | en |
Δημιουργός | Αντωνακακης Μαριος | el |
Δημιουργός | Piastra, Maria Carla 1988- | en |
Δημιουργός | Koulouri Alexandra | en |
Δημιουργός | Wolters Carsten H. | en |
Δημιουργός | Pursiainen, Sampsa | en |
Εκδότης | Elsevier | en |
Περίληψη | This study concerns reconstructing brain activity at various depths based on non-invasive EEG (electroencephalography) scalp measurements. We aimed at demonstrating the potential of the RAMUS (randomized multiresolution scanning) technique in localizing weakly distinguishable far-field sources in combination with coinciding cortical activity. As we have shown earlier theoretically and through simulations, RAMUS is a novel mathematical method that by employing the multigrid concept, allows marginalizing noise and depth bias effects and thus enables the recovery of both cortical and subcortical brain activity. To show this capability with experimental data, we examined the 14–30 ms post-stimulus somatosensory evoked potential (SEP) responses of human median nerve stimulation in three healthy adult subjects. We aim at reconstructing the different response components by evaluating a RAMUS-based estimate for the primary current density in the nervous tissue. We present source reconstructions obtained with RAMUS and compare them with the literature knowledge of the SEP components and the outcome of the unit-noise gain beamformer (UGNB) and standardized low-resolution brain electromagnetic tomography (sLORETA). We also analyzed the effect of the iterative alternating sequential technique, the optimization technique of RAMUS, compared to the classical minimum norm estimation (MNE) technique. Matching with our previous numerical studies, the current results suggest that RAMUS could have the potential to enhance the detection of simultaneous deep and cortical components and the distinction between the evoked sulcal and gyral activity. | en |
Τύπος | Peer-Reviewed Journal Publication | en |
Τύπος | Δημοσίευση σε Περιοδικό με Κριτές | el |
Άδεια Χρήσης | http://creativecommons.org/licenses/by-nc-nd/4.0/ | en |
Ημερομηνία | 2022-08-04 | - |
Ημερομηνία Δημοσίευσης | 2021 | - |
Θεματική Κατηγορία | Electroencephalography (EEG) | en |
Θεματική Κατηγορία | Somatosensory evoked potential (SEP) | en |
Θεματική Κατηγορία | Median nerve stimulation | en |
Θεματική Κατηγορία | Finite element method (FEM) | en |
Θεματική Κατηγορία | Hierarchical Bayesian model (HBM) | en |
Θεματική Κατηγορία | Deep brain activity | en |
Βιβλιογραφική Αναφορά | A. Rezaei, J. Lahtinen, F. Neugebauer, M. Antonakakis, M. C. Piastra, A. Koulouri, C. H. Wolters, and S. Pursiainen, "Reconstructing subcortical and cortical somatosensory activity via the RAMUS inverse source analysis technique using median nerve SEP data," NeuroImage, vol. 245, Dec. 2021. doi: 10.1016/j.neuroimage.2021.118726 | en |