Institutional Repository
Technical University of Crete
EN  |  EL

Search

Browse

My Space

Microsieving of raw sawage at the wastewater treatment plant of Rethymno: Yield and energy content of produced biosolids

Kampourakis Christos

Simple record


URIhttp://purl.tuc.gr/dl/dias/69CE861F-F50D-4DDB-A118-5E4B6BE699D6-
Identifierhttps://doi.org/10.26233/heallink.tuc.94762-
Languageel-
Extent4.1 megabytesen
Extent57 σελίδεςel
TitleΜικροκοσκίνιση πρωτογενών λυμάτων στην εγκατάσταση επεξεργασίας λυμάτων Ρεθύμνου: Απόδοση και ενεργειακό περιεχόμενο παραγόμενων βιοστερεών el
TitleMicrosieving of raw sawage at the wastewater treatment plant of Rethymno: Yield and energy content of produced biosolids en
CreatorKampourakis Christosen
CreatorΚαμπουρακης Χρηστοςel
Contributor [Committee Member]Stefanakis Alexandrosen
Contributor [Committee Member]Στεφανακης Αλεξανδροςel
Contributor [Committee Member]Kalogerakis Nikosen
Contributor [Committee Member]Καλογερακης Νικοςel
Contributor [Thesis Supervisor]Gikas Petrosen
Contributor [Thesis Supervisor]Γκικας Πετροςel
PublisherΠολυτεχνείο Κρήτηςel
PublisherTechnical University of Creteen
Academic UnitΠολυτεχνείο Κρήτης::Σχολή Χημικών Μηχανικών και Μηχανικών Περιβάλλοντοςel
Content SummaryΗ ραγδαία πληθυσμιακή και βιομηχανική ανάπτυξη συμβάλλουν άμεσα στην αύξηση των βιοστερεών που παράγονται καθημερινά. Οι ανάγκες τις οποίες δημιουργεί η συνεχόμενη αυξητική τάση της παραγωγής αποβλήτων, δεν μπορούν να καλυφθούν με τις μεθόδους που χρησιμοποιούνταν στο παρελθόν. Λόγω του αξιόλογου ενεργειακού περιεχομένου των μικροκοσκινισμένων βιοστερεών, προτείνεται ολοκληρωμένη διαχείριση τους με στόχο την παραγωγή ενέργειας, εφαρμόζοντας τις τεχνολογίες της ξήρανσης και της αεριοποίησης. Στην παρούσα διπλωματική εργασία καταγράφηκαν τα χαρακτηριστικά εισερχόμενου- εξερχόμενου αποβλήτου της Εγκατάστασης Επεξεργασίας Λυμάτων (ΕΕΛ) Ρεθύμνου, πραγματοποιήθηκε η παρακολούθηση λειτουργίας - απόδοσης πιλοτικού μικροκόσκινου που είναι εγκατεστημένο στην συγκεκριμένη ΕΕΛ, καθώς και η αξιολόγηση του ενεργειακού περιεχομένου των παραγόμενων μικροκοσκινισμένων βιοστερεών με την προοπτική περαιτέρω αξιοποίησής τους. Πιο συγκεκριμένα, μετρήθηκαν σε δείγματα εισερχόμενου - εξερχόμενου αποβλήτου της ΕΕΛ Ρεθύμνου, τα TSS (170 ± 59 mg/L, 19 ± 11 mg/L), BOD5 (311 ± 46 mg/L, 7 ± 2 mg/L), και COD (199 ± 46 mg/L, 62 ± 18 mg/L), αντίστοιχα. Επίσης, σχετικά με την απόδοση της μικροκοσκίνισης και τα χαρακτηριστικά παραγόμενων βιοστερεών μετρήθηκαν: τα TSS εισόδου (194 ± 51 mg/L) και εξόδου (159 ± 46 mg/L), η υγρασία (M) των μικροκοσκινισμένων βιοστερεών (64 ± 2%), τα VS (90 ± 1% των TS) καθώς και η HHV (21,5 ± 1,4 MJ/kg). Τέλος, λόγω του αξιόλογου ενεργειακού περιεχομένου των μικροκοσκινισμένων βιοστερεών, προτάθηκε ολοκληρωμένη διαχείριση τους με στόχο την παραγωγή ενέργειας, συμπεριλαμβάνοντας τις τεχνολογίες μικροκοσκίνισης-ηλιακής ξήρανσης-αεριοποίησης. Με βάση τους υπολογισμούς που έγιναν, ένα τέτοιο σύστημα μπορεί να λειτουργήσει αυτόνομα, αφού η παραγόμενη ενέργεια αναμένεται να καλύπτει τις ενεργειακές ανάγκες της πιλοτικής διάταξης και κατά συνέπεια να προκαλέσει σημαντική μείωση των συνολικών ενεργειακών αναγκών της ΕΕΛ.el
Content SummaryThe rapid population and industrial growth directly contribute to the increase in the daily produced biosolids. The needs created by the continuous increasing trend of waste production cannot be met by the methods used in the past. Due to the significant energy content of microsieved biosolids, their integrated management is proposed with the aim of energy production, applying drying and gasification technologies. In this thesis, the characteristics of the incoming and outgoing wastewater at the Wastewater Treatment Plant (WWTP) of Rethymno were recorded, the monitoring of the operation and performance of a pilot microsieve installed in this WWTP was carried out, as well as the evaluation of the energy content of the produced micro-sieved biosolids with the perspective of further their utilization. More specifically, the measurements of the incoming and outgoing wastewater of the WWTP of Rethymno resulted to concentration of TSS (170 ± 59 mg/L, 19 ± 11 mg/L), BOD5 (311 ± 46 mg/L, 7 ± 2 mg/L), and COD (199 ± 46 mg/L, 62 ± 18 mg/L), respectively. Also, regarding microsieving performance and produced biosolids characteristics were measured: TSS inlet (194 ± 51 mg/L) and TSS outlet (159 ± 46 mg/L), moisture (M) of microsieved biosolids (64 ± 2% ), VS (90 ± 1% of TS) as well as HHV (21.5 ± 1.4 MJ/kg). Finally, due to the significant energy content of microsieved biosolids, their integrated management was proposed with the aim of energy production, including microsieving-solar drying-gasification technologies. Based on the calculations made, such a system can operate autonomously, since the energy produced is expected to cover the energy needs of the pilot plant and consequently cause a significant reduction in the overall energy needs of WTP.en
Type of ItemΔιπλωματική Εργασίαel
Type of ItemDiploma Worken
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2023-02-07-
Date of Publication2023-
SubjectΕΕΛel
SubjectΒιοστερεάel
SubjectΑεριοποίησηel
SubjectΞήρανσηel
SubjectΕνέργειαel
SubjectΜικροκοσκίνισηel
Bibliographic CitationΧρήστος Καμπουράκης, "Μικροκοσκίνιση πρωτογενών λυμάτων στην εγκατάσταση επεξεργασίας λυμάτων Ρεθύμνου: Απόδοση και ενεργειακό περιεχόμενο παραγόμενων βιοστερεών", Διπλωματική Εργασία, Σχολή Χημικών Μηχανικών και Μηχανικών Περιβάλλοντος, Πολυτεχνείο Κρήτης, Χανιά, Ελλάς, 2023el
Bibliographic CitationChristos Kampourakis, "Microsieving of raw sawage at the wastewater treatment plant of Rethymno: Yield and energy content of produced biosolids", Diploma Work, School of Chemical and Environmental Engineering, Technical University of Crete, Chania, Greece, 2023en

Available Files

Services

Statistics