Application of a handheld X-ray fluorescence analyzer for the quantification of air particulate matter on Teflon filters

Chatoutsidou Sofia-Eirini, Papagiannis Stefanos, Anagnostopoulos Dimitrios F., Eleftheriadis Konstantinos, Lazaridis Michail, Karydas Andreas G.

Simple record


URIhttp://purl.tuc.gr/dl/dias/9EBB8D1F-CD03-4431-85E2-600EC8D6E2D6-
Identifierhttps://doi.org/10.1016/j.sab.2022.106517-
Identifierhttps://www.sciencedirect.com/science/article/pii/S0584854722001616-
Languageen-
Extent9 pagesen
TitleApplication of a handheld X-ray fluorescence analyzer for the quantification of air particulate matter on Teflon filtersen
CreatorChatoutsidou Sofia-Eirinien
CreatorΧατουτσιδου Σοφια-Ειρηνηel
CreatorPapagiannis Stefanosen
CreatorAnagnostopoulos Dimitrios F.en
CreatorEleftheriadis Konstantinosen
CreatorLazaridis Michailen
CreatorΛαζαριδης Μιχαηλel
CreatorKarydas Andreas G.en
PublisherElsevieren
DescriptionThis work was supported by the project “PANhellenic infrastructure for Atmospheric Composition and climatE change” (MIS 5021516) which is implemented under the Action “Reinforcement of the Research and Innovation Infrastructure”, funded by the Operational Programme “Competitiveness, Entrepreneurship and Innovation” (NSRF 2014-2020) and co-financed by Greece and the European Union (European Regional Development Fund). We also acknowledge support of this work by the project CALIBRA/EYIE (MIS 5002799), implemented under Action “Reinforcement of the Research and Innovation Infrastructures,” funded by the Operational Programme “Competitiveness, Entrepreneurship and Innovation” (NSRF 2014-2020) and co-financed by Greece and the European Union (European Regional Development Fund).en
Content SummaryElemental characterization of air particulate matter samples through the application of X-ray fluorescence (XRF) spectrometry is a widespread analytical technique. This work presents the optimization and calibration methodology of a handheld XRF spectrometer and its subsequent application in elemental quantification of unknown particulate matter samples. The optimization of the handheld spectrometer was conducted through investigation of the elemental sensitivities and Limits of Detection (LoD) at variable excitation conditions (voltage, filter). Accordingly, five optimum operating conditions were obtained each one targeted in different elemental range: 1) Z = 11–12, 2) 12 < Z < 17, 3) 16 < Z < 23, 4) 22 < Z < 31 and 5) 30 < Z < 92. Subsequently, a number of reference (5 multi-element and 42 compound/single-element) materials were used to obtain calibration curves for 24 elements (Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Pb). Weighted least-square regression analysis was implemented to best fit the experimentally measured intensities with mass loadings resulting for most of the elements to high correlations (Pearson r > 0.98) and low statistical error. In addition, intercomparison of the elemental concentrations from 28 unknown particulate matter samples between the handheld and a benchtop XRF spectrometer showed good agreement.en
Type of ItemPeer-Reviewed Journal Publicationen
Type of ItemΔημοσίευση σε Περιοδικό με Κριτέςel
Licensehttp://creativecommons.org/licenses/by/4.0/en
Date of Item2024-01-05-
Date of Publication2022-
SubjectHandheld ED-XRF spectrometeren
SubjectOptimizationen
SubjectParticulate matteren
SubjectElemental quantificationen
Bibliographic CitationS. E. Chatoutsidou, S. Papagiannis, D. F. Anagnostopoulos, K. Eleftheriadis, M. Lazaridis, and A. G. Karydas, “Application of a handheld X-ray fluorescence analyzer for the quantification of air particulate matter on Teflon filters,” Spectrochim. Acta, Part B, vol. 196, Oct. 2022, doi: 10.1016/j.sab.2022.106517.en