Ιδρυματικό Αποθετήριο
Πολυτεχνείο Κρήτης
EN  |  EL

Αναζήτηση

Πλοήγηση

Ο Χώρος μου

Quantification of trace transformation products of rocket fuel unsymmetrical dimethylhydrazine in sand using vacuum-assisted headspace solid-phase microextraction

Zhakupbekova Aray, Baimatova Nassiba, Psyllaki Eleftheria, Kenessov Bulat

Απλή Εγγραφή


URIhttp://purl.tuc.gr/dl/dias/52A06935-1370-4283-9BE7-4CB36CAC349F-
Αναγνωριστικόhttps://doi.org/10.1007/s11356-021-17844-1-
Αναγνωριστικόhttps://link.springer.com/article/10.1007/s11356-021-17844-1-
Γλώσσαen-
Μέγεθος12 pagesen
ΤίτλοςQuantification of trace transformation products of rocket fuel unsymmetrical dimethylhydrazine in sand using vacuum-assisted headspace solid-phase microextractionen
ΔημιουργόςZhakupbekova Arayen
ΔημιουργόςBaimatova Nassibaen
ΔημιουργόςPsyllaki Eleftheriaen
ΔημιουργόςΨυλλακη Ελευθεριαel
ΔημιουργόςKenessov Bulaten
ΕκδότηςSpringeren
ΠερίληψηQuantification of unsymmetrical dimethylhydrazine transformation products in solid samples is an important stage in monitoring of environmental pollution caused by heavy rockets launches. The new method for simultaneous quantification of unsymmetrical dimethylhydrazine transformation products in sand samples using vacuum-assisted headspace solid-phase microextraction without addition of water followed by gas chromatography-mass spectrometry is proposed. Decreasing air evacuation time from 120 to 20 s at 23 °C resulted in increased responses of analytes by 25–46% and allowed obtaining similar responses as after evacuation at −30 °C. The best combination of responses of analytes and their relative standard deviations (RSDs) was achieved after air evacuation of a sample (m = 1.00 g) for 20 s at 23 °C, incubation for 30 min at 40 °C, and 30-min extraction at 40 °C by Carboxen/polydimethylsiloxane (Car/PDMS) fiber. The method was validated in terms of linearity (R2=0.9912–0.9938), limits of detection (0.035 to 3.6 ng g−1), limits of quantification (0.12–12 ng g−1), recovery (84–97% with RSDs 1–11%), repeatability (RSDs 3–9%), and reproducibility (RSDs 7–11%). It has a number of major advantages over existing methods based on headspace solid-phase microextraction—lower detection limits, better accuracy and precision at similar or lower cost of sample preparation. The developed method was successfully applied for studying losses of analytes from open vials with model sand spiked with unsymmetrical dimethylhydrazine transformation products. It can be recommended for analysis of trace concentrations of unsymmetrical dimethylhydrazine transformation products when studying their transformation, migration and distribution in contaminated sand.en
ΤύποςPeer-Reviewed Journal Publicationen
ΤύποςΔημοσίευση σε Περιοδικό με Κριτέςel
Άδεια Χρήσηςhttp://creativecommons.org/licenses/by/4.0/en
Ημερομηνία2024-02-22-
Ημερομηνία Δημοσίευσης2022-
Θεματική ΚατηγορίαVacuum-assisted headspace solid-phase microextractionen
Θεματική ΚατηγορίαGas chromatography-mass spectrometryen
Θεματική ΚατηγορίαSoil analysisen
Θεματική ΚατηγορίαTransformation productsen
Θεματική ΚατηγορίαDimethylhydrazineen
Θεματική ΚατηγορίαRocket fuelen
Βιβλιογραφική ΑναφοράA. Zhakupbekova, N. Baimatova, E. Psillakis and B. Kenessov, “Quantification of trace transformation products of rocket fuel unsymmetrical dimethylhydrazine in sand using vacuum-assisted headspace solid-phase microextraction,” Environ. Sci. Pollut. Res., vol. 29, no. 22, pp. 33645–33656, May 2022, doi: 10.1007/s11356-021-17844-1.en

Υπηρεσίες

Στατιστικά