Ιδρυματικό Αποθετήριο
Πολυτεχνείο Κρήτης
EN  |  EL

Αναζήτηση

Πλοήγηση

Ο Χώρος μου

Relationship between airborne microbial and particulate matter concentrations in the ambient air at a Meditearranean site

Lazaridis Michalis, Katsivela, Eleftheria, 1961-, Frueherer Name, Raisi ,L

Πλήρης Εγγραφή


URI: http://purl.tuc.gr/dl/dias/2194D0BE-DFCE-4086-ADE6-016C97670ECE
Έτος 2010
Τύπος Δημοσίευση σε Περιοδικό με Κριτές
Άδεια Χρήσης
Λεπτομέρειες
Βιβλιογραφική Αναφορά L. Raisi,M. Lazaridis, E. Katsivela.(2010). Relationship between airborne microbial and particulate matter concentrations in the ambient air at a Meditearranean site. Global Nest Journal [online].pp.84-91.Available:http://journal.gnest.org/sites/default/files/Journal%20Papers/84-91_694_Katsivela_12-1.pdf
Εμφανίζεται στις Συλλογές

Περίληψη

The relationship between the viable airborne bacterial and fungal concentrations and therespirable particulate matter with aerodynamic diameter less than 10 µm (PM10), 2.5 µm(PM2.5), and 1 µm (PM1) in the ambient air was studied. An Andersen six stage viable particlesampler and a MAS 100 sampler were used for microbial measurements. Duplicates ofsamples were collected at each sampling period (20 campaigns in total) at a residential site inthe city of Chania (Crete, Greece) during April, May and June 2008.Mean concentration of the total sum of the six size fractions was 79 + 41 CFU m-3 formesophilic heterotrophic bacteria, whereas for mesophilic fungi it was five times higher (395 +338 CFU m-3). Particulate matter measurements at the same time period at the same siterevealed that the mean concentrations of PM10, PM2.5, and PM1 were 46 + 14, 35 + 14, and 28+ 12 µg m-3, respectively, whereas the mean cumulate counts of PM1 particles was 5,059 +1,973 particles cm-3. The mean arithmetic concentration of the size distribution of the airbornefungi had a maximum at aerodynamic diameters between 2.1 and 3.3 µm. However, amaximum was not observed for the mean arithmetic concentration of the size distribution ofthe airborne heterotrophic bacteria. It was also observed that concentrations of airbornebacteria and fungi outdoors were highly variable and do not correlate with the particle number(PM1) or mass concentration of PM10, PM2.5 and PM1. Thereby, the R2-values in allcorrelations were less than 0.3. However, the concentrations of airborne bacteria and fungiwere decreased with increasing mass concentrations of PM10, PM2.5, or PM1 while wereincreased with increasing number concentration of PM1. In addition, the concentrations ofairborne bacteria were increased with increasing concentrations of airborne fungi. Finally, themicrobial or the particulate matter data did not correlate with meteorological parameters, suchas temperature, relative humidity, wind speed and UV radiation in ambient conditions.

Υπηρεσίες

Στατιστικά