Το έργο με τίτλο On-line leak monitoring in fluid pumping systems από τον/τους δημιουργό/ούς Pouliezos Anastasios, Stavrakakis Georgios, Mathioudakis, K διατίθεται με την άδεια Creative Commons Αναφορά Δημιουργού 4.0 Διεθνές
Βιβλιογραφική Αναφορά
A. Pouliezos, G. Stavrakakis, K. Mathioudakis,"On-line leak monitoring in fluid pumping systems ," Intern.J.of Modelling and Sim., vol. 20, no. 3,pp. 213-220 ,2000.doi:10.1080/02286203.2000.11442159
https://doi.org/10.1080/02286203.2000.11442159
In this paper, a model-based leak detection methodology for fluid pumping systems is developed. The novelty of this approach lies in modelling the leak position as a point between a real and an imaginary valve. The equations that describe the resulting dynamic system are then put into an input-output form suitable for least squares estimation. In this way, classic parameter-estimation based detection methods are applied to moving windows of system data. Computer simulation illustrates the feasibility of the method.